Document Type : Original Article
Authors
Department of Orthodontics, Faculty of Dentistry, Cairo University, Cairo, Egypt.
Abstract
Keywords
Main Subjects
Introduction
Class II malocclusion is the second most prevalent type of malocclusion which is seen in almost the third of the population and have many components which are usually expressed simultaneously, but to different extents( Proffit WR, Fields H, 2013). The dental component is characterized as distal relationship of mandibular teeth relative to maxillary teeth. The skeletal component is either maxillary protrusion or mandibular retrusion and sometimes there is combination of both (MCNAMARA, 1981; Bishara, 2006). Abnormal vertical facial heights are common in the class II malocclusion most probably exhibit excessive vertical development. Individuals with Class II malocclusion have functional deficits and impaired masticatory function. (Toro et al., 2006)
Functional appliances can be used in case of mandibular retrusion to reposition the mandible in a forward direction in an attempt to stimulate condylar growth. The second option is the use of headgears in cases of maxillary protrusion to redirect the growth of the maxillary complex or drive the maxillary teeth distally with extraoral anchorage traction, while the mandible continues its forward growth.
High pull head gears are indicated in subjects with increased vertical growth pattern. Studies reported their effects to include restriction of the maxillary anterior growth, slight clockwise rotation of the palatal plane, distalization and maintenance of the vertical position of upper molars and reduction of the ANB angle.(Firouz, Zernik and Nanda, 1992; Uner and Yucel-Eroglu, 1996). The problems with headgears include unaesthetic appearance and that they rely heavily on patient cooperation, as a lack of compliance may compromise the outcome.(Egolf, BeGole and Upshaw, 1990) Studies recommended a minimum of 12 hours daily to achieve the desired results (Firouz, Zernik and Nanda, 1992). An additional disadvantage to headgear treatment is the risk of facial injury.(Samuels, Orth and Orth, 1996)
The zygomatic buttress has been recommended by many working groups as a site for mini-plate placement referred to as zygomatic anchorage systems. With its thick cortical plate, the zygomatic process of the maxilla enables the anchorage device to be placed at a distance far from the developing teeth in a growing patient while maintaining better stability for anchor units under high forces (Rigolizzo et al., 2005; Sugawara et al., 2006; Liou et al., 2007; Kaya et al., 2009; Ghosh, 2018). Many authors used this site for anchorage in distalization and intrusion of maxillary molars in adults (Veziroglu et al., 2008; Nur et al., 2012). So in this study we investigated the use of infra-zygomatic mini-screws as skeletal anchorage in a modified appliance as compared to the removable high pull headgear in growing class II subjects.
Subjects and Methods
Study design:
This study was designed as an interventional, parallel randomized, controlled trial with 1:1 allocation ratio.
Eligibility criteria:
All the recruited subjects followed the inclusion criteria of:
And exclusion criteria of:
Study setting:
It took place at the Department of Orthodontics outpatient clinic of the educational hospital of the Faculty of Dentistry, Cairo University. This study was approved by the Research Ethics Committee of the Faculty of Dentistry, Cairo University. All patients and volunteers were informed about the study procedures and informed written consents were signed by their guardians.
Trial registration:
www.clinicaltrial.gov with number: NCT03839303
Interventions:
Initial records in both groups:
In the intervention group: (fig.1,2)
Fig.1: intraoral frontal view of the mini-screws appliance
Fig.2: extra oral frontal view of the mini-screws appliance (smiling)
In the headgear group: (fig.3,4)
Fig.3: occlusal view of the intraoral splint on a cast
Fig.4: extra oral frontal view of headgear appliance (smiling)
In both groups:
Lateral cephalogram analysis:
A customized digital analysis was made by Facad (Version 3.11,ILEXIS AB, Sweden) software to analyse the data from T1 and T2 lateral cephalograms in both groups
Methods of measuring the outcomes (fig.5):
Fig.5: cephalometric measurements and reference planes: 1- S VRL reference line (line perpendicular to HRL passing through sella point), 2- HRL reference line (line between porion and orbitale points), 3- palatal plane (line between anterior and posterior nasal spine points), 4- Cen U6-HRL ( The linear distance between the point of furcation of buccal roots of upper first molar and the horizontal reference line) , 5- Cen U6-S VRL (The linear distance between the point of furcation of buccal roots of upper first molar and the vertical reference line), 6- U6 tipping (Angle formed between the long axis of upper first molar and palatal plane)
Sample Size calculation:
Sample size was calculated by G power software. It was found that the group sample sizes of 10 and 10 can achieve 80% power to reject the null hypothesis of equal means when the effect size is 1.367 with a significance level (alpha) of 0.050 using a two-tailed two-sample equal-variance t-test.
Randomization:
The randomization was performed with a 1:1 ratio of allocation, the sequence was computer generated. The method of randomization was carried out through randomizer.org website
The randomization numbers produced from the sequence generation were written on opaque papers and folded 4 times and sealed in opaque envelopes and kept in a sealed box. Each patient was then allowed to choose one of the sealed envelopes to be allocated to one of the two study groups.
Blinding:
To participant (subjects):
Patients can detect the type of the intervention, so blinding is not possible.
To operator:
The main operator is responsible for the intervention, so his blinding is not possible.
To Assessor:
The 2 assessors (not involved in the study) carried out the measurements blindly on the pre and post treatment radiographs.
Statistical analysis:
Results
Baseline analysis: Showed no statistically significance difference between the two groups where (p value > 0.05).
Intervention (mini-screws) group: (Table 1)
Table 1: Table showing relationship between the pre and post readings in different parameters in mini-screws group
Measurement |
Mini-screws group |
Min. |
Max. |
Mean |
S.D. |
Mean diff. |
p-value |
95% confidence interval of mean difference |
|
Lower |
Upper |
||||||||
U6-tipping |
Pre |
-106.4 |
-79.9 |
-96.67 |
7.72 |
-4.72 |
0.182 |
-2.609 |
12.046 |
Post |
-117.6 |
-89.3 |
-101.39 |
8.38 |
|||||
Cen-U6-S-VRL |
Pre |
33.4 |
51.8 |
39.72 |
5.28 |
-1.53 |
0.103 |
-0.371 |
3.426 |
Post |
31.2 |
52.5 |
38.19 |
5.85 |
|||||
Cen-U6-HRL |
Pre |
26.4 |
37.4 |
29.85 |
3.49 |
-0.74 |
0.276 |
-0.689 |
2.161 |
Post |
25 |
39.9 |
29.12 |
4.6 |
SD= Standard deviation, Min.= Minimum value, Max.= Maximum value, *; significant (p≤ 0.05) ns; non-significant (p>0.05)
Control (headgear) group: (Table 2)
Table 2: Table showing relationship between the pre and post readings in different parameters in headgear group
Measurement |
Headgear group |
Min. |
Max. |
Mean |
S.D. |
Mean diff |
p-value |
95% confidence interval of mean difference |
|
Lower |
Upper |
||||||||
U6-tipping |
Pre |
-110.4 |
-93.1 |
-101.97 |
5.74 |
-3.63 |
0.02* |
0.694 |
6.561 |
Post |
-124.2 |
-96 |
-105.6 |
7.7 |
|||||
Cen-U6-S-VRL |
Pre |
34.7 |
41.9 |
37.81 |
2.28 |
-2.58 |
0.004* |
1.03 |
4.134 |
Post |
31 |
37.5 |
35.23 |
2.09 |
|||||
Cen-U6-HRL |
Pre |
27.8 |
40 |
32.3 |
3.76 |
-0.20 |
0.735 |
-1.079 |
1.479 |
Post |
26.9 |
36.6 |
32.1 |
3.46 |
S.D.= Standard deviation, Min.= Minimum value, Max.= Maximum value, *; significant (p≤ 0.05) ns; non-significant (p>0.05)
There were no significant differences when the changes after treatment in the two groups were compared. (Table 3)
Table 3: Table showing relationship between the headgear and mini-screws readings in different parameters.
Measurement |
Change |
Min. |
Max. |
Mean |
S.D. |
p-value |
95% confidence interval of mean difference |
|
Lower |
Upper |
|||||||
U6-tipping |
Headgear |
-13.80 |
2.10 |
-3.63 |
4.37 |
0.761 |
-6.298 |
8.480 |
Mini-screw |
-20.70 |
13.50 |
-4.72 |
10.91 |
||||
Cen-U6-S-VRL |
Headgear |
-7.80 |
0.40 |
-2.58 |
2.31 |
0.349 |
-3.350 |
1.241 |
Mini-screw |
-7.40 |
2.10 |
-1.53 |
2.83 |
||||
Cen-U6-HRL |
Headgear |
-3.40 |
3.10 |
-0.20 |
1.90 |
0.540 |
-1.256 |
2.329 |
Mini-screw |
-4.10 |
2.50 |
-0.74 |
2.12 |
S.D.= Standard deviation., Min.= Minimum value, Max.= Maximum value.
*; significant (p≤ 0.05) ns; non-significant (p>0.05)
Discussion
Many orthodontic appliances were designed for treatment of class ⅠⅠ div 1 malocclusion. The choice of the appliance depend on the components of class ⅠⅠ in each case. Headgear appliance is one of the most used appliances especially in case of maxillary skeletal prognathism. The major problem with headgear is that it depends on patient cooperation as it should be worn for several hours daily for months to produce its effect(Brandao, Pinho and Urias, 2006)
The proposed appliance in the present study is considered a modification of the appliance designed by Nur et al. (Nur, Bayram and Pampu, 2010; Nur et al., 2012) for distalization of maxillary molars. The differences between the two appliances are that in the present study infrazygomatic mini-screws were used for anchorage, gabble bend was used as stopper for the wire, the direction of the anterior hooks for traction was incisaly and the hooks were placed at the incisal edge level of the upper incisors and the four incisors were bonded and ligated as a one unit with the appliance, instead of infrazygomatic mini-plates for anchorage(need surgical procedures for insertion and removal), bayonet bend as a stopper, the direction of anterior hooks was apically and the incisors were not bonded in the zygoma gear appliance.
upper first molar distalization was the first main outcome in the study and the results showed that it was achieved by 2.58 ± 2.31 mm with 3.63º of distal tipping in the headgear group and this comes in agreement with Firouz et al.(Firouz, Zernik and Nanda, 1992) who showed 2.56 mm of molar distalization with also slight change in axial inclination. Watson(Watson, 1972) also found an average of 3.0 mm of distal maxillary molar movement over a period of 5 to 16 months but with higher forces and more hours of wearing the appliance.
In the mini-screws group the amount of distalization (fig.6) were 1.53 ± 2.83 mm with 4.72º of distal tipping, although that this distalization amount was much less than shown byNur et al.(Nur et al., 2012) and B. Kaya et al.(Kaya et al., 2009) in their studies as they showed 4.37 mm and 5.03 mm of distalization respectively with 3.30º and 5.43º of distal tipping respectively but this can be explained by two things. First, the measurements of the distalization on lateral cephalogram was different in the studies. In the present study the distance between the centroid point of upper first molar to vertical reference plane was used while in the other studies the distance between mesial surface of the crown of upper first molar and vertical reference plane was used. So the tipping might have exaggerated the measurements in the other studies. The second explanation is that there were different line of action of force in the studies. In the present study the force had more intrusion and less distal component than the other studies. El Dawlatly et al.(El-Dawlatly et al., 2014) showed distalization by 2.92 ± 0.69 mm with 1.2º tipping.
Fig.6: intraoral left side photos pretreatment (a) and post treatment with appliance (b)
In comparison with other non-compliance appliances for molar distalization, Antonarakis and Kiliaridis (Antonarakis and Kiliaridis, 2008) showed in their systematic review that when the appliances without skeletal anchorage were considered together, first molars were noted to demonstrate a mean of 2.9 mm of distal movement with an associated 5.4º of distal tipping but with mesial movement of premolars as loss of anchorage.
Both groups showed statistically insignificant upper first molar intrusion, it was 0.2 mm for headgear group and 0.74 mm for the mini-screws group. This results comes into agreement withFirouz et al. (Firouz, Zernik and Nanda, 1992) who showed 0.54 mm of intrusion, with Helder B. Jacob et al.(Jacob, Buschang and dos Santos-Pinto, 2013) who showed maxillary molar intrusion (between 0.4 and 0.7 mm) and with Nur et al.(Nur et al., 2012) who showed 0.5 mm of intrusion. It worth to mention that the control group who did not receive treatment in those studies showed extrusion of maxillary molars. Watson(Watson, 1972) showed 4 mm of intrusion but with much higher forces and longer duration of treatment. In contrary Zervas et al.(Zervas et al., 2016) showed extrusion of upper first molar by 1.14 mm and Almeida-Pedrin et al.(Almeida et al., 2004) showed extrusion by 0.69 mm after treatment with headgear with bite plane. El Dawlatly et al.(El-Dawlatly et al., 2014) showed extrusion by 1.57 mm.
Conclusions:
Within the limitations of the current study, the following conclusions could be withdrawn: